A.X MAT EP
Synopsis: Medical data acquisition under various physical workload conditions & demonstration of biomedical telemetry
Institution (PI): Medical University Innsbruck (Thomas Luger)
Responsible on-site: Ulrich Luger
Description
Test sequence 1 – emergency biomedical telemetry
The test subjects will undergo a sequence of well-defined physiological workload patternsm, whilst the routine monitoring data stream will be relayed to the biomedical engineering team (BME). Data will be stored locally and in the OPS.
Group 1: continuous data recording (verum group)
Group 2: continuous recording via cable telemetry (control group)
Group 3: sporadic recording of data, including voice transmissions (back-up group) Group 4: sporadic recording of data locally only (back-up control group)
Testsequence 2 – environmental parameters
Biomedical telemetry data will be recorded in the closed suit using a data generator without the suit tester inside. A data transfer will be demonstrated between the suit, OPS and MSC server.
Group 1: data recording with data transfer over large distances (verum group) Group 2: data recording with cables in-situ (control group)
Group 3: sporadic data recording with voice communication (bakup group) Group 4: sporadic data recording in-situ (backup control group)
All tests are performed on a daily basis before and after the EVA’s on all test subjects.
- Basic biomedical monitoring: RR, HR, SpO2, Capnometry, temperature)
- Suit in-situ monitoring: Humidity, O2, CO2, temperature.
Sporadic recording
- Questionnaire „well being“ scale on various subjective parameters
- Comparison monitoring with hemodynamical parameters.
Experiment Data
Directories/files | Description |
---|---|
A.X MAT EP | <none> |